mcp-io-hid
prototype
Hands on the keyboard and mouse. A single box that acts as a keyboard and mouse over USB and Bluetooth LE at the same time. The mouse is absolute: the LLM clicks straight at (x, y) from a capture, with no drift from pointer acceleration. Nothing to install on the target: PC, server, HMI or kiosk.
- USB: recognized as a standard device, works from the BIOS/UEFI onward and on any OS, no driver needed.
- Bluetooth LE: no cable to the target; requires pairing through the OS, so no BIOS access.
Specs
- ESP32-S3: native USB OTG (HID keyboard + absolute mouse) and HID over BLE, simultaneously
- 2.4 GHz Wi-Fi, Streamable HTTP MCP server
- Keyboard layouts
us and fr
- Arm / disarm button, status LED
- Powered by the target's USB port (or any USB charger when used over Bluetooth only)
mcp-io-cam
prototype
Eyes on the physical world. A camera the LLM queries on demand, pointed at whatever no wire can read: the workbench, a 3D printer, a server room, or a machine (control panel, indicator lamps, pressure gauge, 7-segment display, HMI screen). No wiring needed. Images come back as MCP image content. Reading a screen through a camera is still less crisp than an HDMI capture (glare, moiré).
Specs
- ESP32-S3 + OV5640 sensor (5 MP, autofocus)
- JPEG encoded by the sensor
- Controllable illumination LED
- No capture possible while disarmed (logical shutter)
- 2.4 GHz Wi-Fi, USB powered
mcp-io-hdmi
in development
Eyes on the screen. Captures the target machine's video output and hands it to the LLM as one-off snapshots, resized for models. No video streaming: roughly one frame per second is plenty for an LLM. DisplayPort through a DP-to-HDMI adapter, VGA through a converter (see mcp-io-vga).
Specs
- ESP32-P4 (hardware JPEG encoder) + MS2130 capture chip
- HDMI input; DisplayPort via adapter, VGA via converter
- Wi-Fi through an ESP32-C6 coprocessor
- HDCP-protected content is not captured
mcp-io-vga
in development
For machines that predate HDMI. The mcp-io-hdmi module with a VGA converter built into the enclosure: industrial HMIs and PCs, supervision stations, old servers, lab equipment that isn't going anywhere.
MCP tools
Same as mcp-io-hdmi: screen_capture, capture_info, device_status.
Specs
- Based on
mcp-io-hdmi (ESP32-P4 + MS2130)
- VGA-to-HDMI converter built into the enclosure
- VGA input (DE-15)
mcp-io-analog
industrial: in development
Hands on electronics and inside the electrical cabinet. Digital I/O, analog measurements, PWM and I2C driven by the LLM: for a lab circuit, a test bench, or a legacy machine whose lamps and sensors it reads and whose buttons it presses through relays. The LLM doesn't juggle pin numbers or millivolts, it works with named channels: hydraulic_pressure = 182 bar, fault_lamp = FAULT.
Industrial version in development
- Isolated 24 V digital inputs (optocouplers): indicator lamps, stack lights, limit switches, PLC outputs
- Relay outputs (dry contacts), limited to 24 V / SELV in v1
- 4 analog inputs, 0-10 V or 4-20 mA, 16-bit ADS1115 ADC
- 24 V supply, DIN-rail housing, pluggable terminal blocks
- Optional RS-485 (Modbus RTU, future firmware update)
Lab version prototype
- ESP32-S3, 3.3 V logic, USB powered
- GPIO, ADC, PWM, DAC (chip dependent), I2C bus
- For electronics work, mock-ups and prototyping
- Same firmware and named channels as the industrial version
Named channels (use these first)
Low-level tools
What channels do
channel_define: digital_in, digital_out or analog_in (GPIO or ADS1115), inversion, on/off labels, linear scaling from mV to engineering units
- Example: 4-20 mA across a 150 Ω shunt, i.e. 600-3000 mV → 0-250 bar
channel_write: on/off, or a pulse_ms pulse to “press” a button through a relay
wait_for: waits until a channel turns on/off or crosses a threshold (60 s max)
- Fault flag when an analog signal is out of range (4-20 mA wire break)
# Example: hydraulic press
channel_define {"name":"fault_lamp","type":"digital_in","pin":4,"invert":true,"on_label":"FAULT","off_label":"OK"}
channel_define {"name":"cycle_running","type":"digital_in","pin":5,"invert":true}
channel_define {"name":"hydraulic_pressure","type":"analog_in","source":"ads1115","ads_channel":0,
"in_min_mv":600,"in_max_mv":3000,"out_min":0,"out_max":250,"unit":"bar"}
channel_define {"name":"cycle_start_button","type":"digital_out","pin":38}
channel_write {"name":"cycle_start_button","on":true,"pulse_ms":300}
wait_for {"name":"cycle_running","condition":"off","timeout_s":60}
Machine safety: outputs are wired in parallel with the normal controls (control panel push buttons), never into a safety chain: emergency stop, guard interlock, light curtain. Cabinet wiring must be done by a qualified person. Lab version: 3.3 V maximum on every terminal, never connect 5 V directly or mains voltage.