Modules

A modular range, one MCP server per box

Each module exposes its own MCP tools on POST /mcp, protected by a token. Status: prototype working on the bench, in development design or proof of concept under way.

mcp-io-hid

prototype

Hands on the keyboard and mouse. A single box that acts as a keyboard and mouse over USB and Bluetooth LE at the same time. The mouse is absolute: the LLM clicks straight at (x, y) from a capture, with no drift from pointer acceleration. Nothing to install on the target: PC, server, HMI or kiosk.

  • USB: recognized as a standard device, works from the BIOS/UEFI onward and on any OS, no driver needed.
  • Bluetooth LE: no cable to the target; requires pairing through the OS, so no BIOS access.

MCP tools

  • keyboard_type
  • keyboard_key
  • mouse_move
  • mouse_click
  • mouse_drag
  • mouse_scroll
  • set_screen_size
  • set_keyboard_layout
  • device_status

Specs

  • ESP32-S3: native USB OTG (HID keyboard + absolute mouse) and HID over BLE, simultaneously
  • 2.4 GHz Wi-Fi, Streamable HTTP MCP server
  • Keyboard layouts us and fr
  • Arm / disarm button, status LED
  • Powered by the target's USB port (or any USB charger when used over Bluetooth only)

mcp-io-cam

prototype

Eyes on the physical world. A camera the LLM queries on demand, pointed at whatever no wire can read: the workbench, a 3D printer, a server room, or a machine (control panel, indicator lamps, pressure gauge, 7-segment display, HMI screen). No wiring needed. Images come back as MCP image content. Reading a screen through a camera is still less crisp than an HDMI capture (glare, moiré).

MCP tools

  • camera_capture
  • camera_settings
  • camera_flash
  • device_status

Specs

  • ESP32-S3 + OV5640 sensor (5 MP, autofocus)
  • JPEG encoded by the sensor
  • Controllable illumination LED
  • No capture possible while disarmed (logical shutter)
  • 2.4 GHz Wi-Fi, USB powered

mcp-io-hdmi

in development

Eyes on the screen. Captures the target machine's video output and hands it to the LLM as one-off snapshots, resized for models. No video streaming: roughly one frame per second is plenty for an LLM. DisplayPort through a DP-to-HDMI adapter, VGA through a converter (see mcp-io-vga).

MCP tools

  • screen_capture
  • capture_info
  • device_status

Specs

  • ESP32-P4 (hardware JPEG encoder) + MS2130 capture chip
  • HDMI input; DisplayPort via adapter, VGA via converter
  • Wi-Fi through an ESP32-C6 coprocessor
  • HDCP-protected content is not captured

mcp-io-vga

in development

For machines that predate HDMI. The mcp-io-hdmi module with a VGA converter built into the enclosure: industrial HMIs and PCs, supervision stations, old servers, lab equipment that isn't going anywhere.

MCP tools

Same as mcp-io-hdmi: screen_capture, capture_info, device_status.

Specs

  • Based on mcp-io-hdmi (ESP32-P4 + MS2130)
  • VGA-to-HDMI converter built into the enclosure
  • VGA input (DE-15)

mcp-io-analog

industrial: in development

Hands on electronics and inside the electrical cabinet. Digital I/O, analog measurements, PWM and I2C driven by the LLM: for a lab circuit, a test bench, or a legacy machine whose lamps and sensors it reads and whose buttons it presses through relays. The LLM doesn't juggle pin numbers or millivolts, it works with named channels: hydraulic_pressure = 182 bar, fault_lamp = FAULT.

Industrial version in development

  • Isolated 24 V digital inputs (optocouplers): indicator lamps, stack lights, limit switches, PLC outputs
  • Relay outputs (dry contacts), limited to 24 V / SELV in v1
  • 4 analog inputs, 0-10 V or 4-20 mA, 16-bit ADS1115 ADC
  • 24 V supply, DIN-rail housing, pluggable terminal blocks
  • Optional RS-485 (Modbus RTU, future firmware update)

Lab version prototype

  • ESP32-S3, 3.3 V logic, USB powered
  • GPIO, ADC, PWM, DAC (chip dependent), I2C bus
  • For electronics work, mock-ups and prototyping
  • Same firmware and named channels as the industrial version

Named channels (use these first)

  • channels_list
  • channels_read
  • channel_write
  • wait_for
  • channel_define
  • channel_delete

Low-level tools

  • list_pins
  • gpio_mode
  • gpio_write
  • gpio_read
  • adc_read
  • pwm_write
  • dac_write
  • i2c_scan
  • i2c_read
  • i2c_write
  • config_save
  • config_clear
  • device_status

What channels do

  • channel_define: digital_in, digital_out or analog_in (GPIO or ADS1115), inversion, on/off labels, linear scaling from mV to engineering units
  • Example: 4-20 mA across a 150 Ω shunt, i.e. 600-3000 mV → 0-250 bar
  • channel_write: on/off, or a pulse_ms pulse to “press” a button through a relay
  • wait_for: waits until a channel turns on/off or crosses a threshold (60 s max)
  • Fault flag when an analog signal is out of range (4-20 mA wire break)
# Example: hydraulic press
channel_define {"name":"fault_lamp","type":"digital_in","pin":4,"invert":true,"on_label":"FAULT","off_label":"OK"}
channel_define {"name":"cycle_running","type":"digital_in","pin":5,"invert":true}
channel_define {"name":"hydraulic_pressure","type":"analog_in","source":"ads1115","ads_channel":0,
                "in_min_mv":600,"in_max_mv":3000,"out_min":0,"out_max":250,"unit":"bar"}
channel_define {"name":"cycle_start_button","type":"digital_out","pin":38}
channel_write  {"name":"cycle_start_button","on":true,"pulse_ms":300}
wait_for       {"name":"cycle_running","condition":"off","timeout_s":60}

Machine safety: outputs are wired in parallel with the normal controls (control panel push buttons), never into a safety chain: emergency stop, guard interlock, light curtain. Cabinet wiring must be done by a qualified person. Lab version: 3.3 V maximum on every terminal, never connect 5 V directly or mains voltage.

Prototype stage. Specs may change until the production release. Want to help? See Support the project.